1 Department of Anesthesiology, Tri-Service General Hospital and Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei, Taiwan
2 Division of Thoracic Surgery, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan
3 Department of Anesthesiology, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan

Correspondence Address:
Dr. Zhi-Fu Wu
Department of Anesthesiology, Tri-Service General Hospital and National Defense Medical Center, #325, Section 2, Chenggung Road, Neihu 114, Taipei
Taiwan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmedsci.jmedsci_166_18

Rights and Permissions

Objective: The aim of this study is to use stroke volume variation (SVV) as an indicator to predict fluid responsiveness in patients undergoing protective one-lung ventilation (OLV) in pressure-controlled ventilation mode. Design and Setting: A prospective clinical study in an operating room in a medical center. Patients: Fourteen patients receiving video-assisted thoracic surgery while undergoing OLV in pressure-controlled ventilation mode. Methods: After starting OLV in pressure-controlled ventilation mode, all patients were administered 6 ml/kg 6% hydroxyethyl starch for 20 min. Vigileo-FloTrac system was used to record hemodynamic variables before and after volume loading. The ability of SVV to predict fluid responsiveness was tested by calculating the area under the receiver operating characteristic (ROC) curve for an increase in stroke volume index of ≥10% after volume loading, and the optimal threshold value of SVV was calculated. Results: The area under the ROC curve for SVV to discriminate between responders and nonresponders was 0.89 (95% confidence interval, 0.700–1; P = 0.03). The optimal threshold value of SVV was 8.5% (sensitivity 88.89%; specificity 75%). Conclusions: SVV may be suitable for predicting fluid responsiveness in patients undergoing protective OLV in pressure-controlled ventilation mode.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed446    
    Printed45    
    Emailed0    
    PDF Downloaded85    
    Comments [Add]    

Recommend this journal